LostPennyFPVLiPo fleet health

156 rows · 14 nights · ingest 2026-09-30

C1 and C2 · CNHL Black Series V2

Fleet health

Twelve packs, read from iCharger DX8 storage charges. Calls below are the live status table. Charts use the IR store and leave partial nights as gaps.

OK

7

C1-P2 · C1-P6 · C2-P1 · C2-P3 · C2-P4 · C2-P5 · C2-P6

Caution

3

C1-P3 · C1-P4 · C2-P2

OFF

2

C1-P1 · C1-P5

Last C1 night

2026-09-27

Call date 2026-09-27

Last C2 night

2026-09-30

Call date 2026-09-30

Mean IR

536.9mΩ

Mean of the 12 latest pack averages

Measured packs only

Fleet mean IR

mΩ · gaps are unmeasured nights

Mean pack IR for C1 and C2 across sessions Arrow keys move between sessions. Gaps are nights that pack or fleet was not measured.

500520540560580
S263S287S308S329S344S358S372S386S400S41309-26*09-26e09-2709-30*

Next parallel

Board call from the status file. Rest-Δ here can drop packs marked OFF. The Rule B chart further down is the full measured set.

Packs

C1

C2

Status calls

Verbatim from the status file. C1 as of 2026-09-27. C2 as of 2026-09-30. Latest IR, spread, and floor are each pack's last measured night, shown beside the call.

Chronic Cell6 self-discharge (floor 3509 mV, imb 191 mV ≥~150 SD)

worse vs eve

Call 2026-09-27 · IR 550.0 · spr 42 · floor 3509

spr 26; floor OK

Call 2026-09-27 · IR 564.2 · spr 26 · floor 3634

C1-P3Caution

spr 40 + floor 3578 EYE (<3600); imb 122 not SD — still ON next board

Call 2026-09-27 · IR 512.2 · spr 40 · floor 3578

C1-P4Caution

Chronic Cell1 pack-max IR 561; spr 45 Caution; floor OK (not SD); reduced C1 amps; not scrap

Call 2026-09-27 · IR 533.8 · spr 45 · floor 3603

floor 3539 EYE + lowest rest; spr 33 Go / imb 71 not SD — not scrap; off keeps board rest-Δ GO (prefer off tonight)

Call 2026-09-27 · IR 569.5 · spr 33 · floor 3539

spr 16

Call 2026-09-27 · IR 551.7 · spr 16 · floor 3644

spr 17

Call 2026-09-30 · IR 498.7 · spr 17 · floor 3698

C2-P2Caution

floor 3597 EYE; imb 103 not SD; spr 26 Go — still ON

Call 2026-09-30 · IR 528.2 · spr 26 · floor 3597

spr 26

Call 2026-09-30 · IR 563.5 · spr 26 · floor 3661

spr 17

Call 2026-09-30 · IR 539.2 · spr 17 · floor 3686

spr 19

Call 2026-09-30 · IR 536.0 · spr 19 · floor 3681

spr 18; lowest C2 pack avg

Call 2026-09-30 · IR 495.3 · spr 18 · floor 3694

Latest night per pack

Cell IR heatmap

483 mΩ587 mΩ

Color is this fleet's latest-cell range, cooler for lower IR. C1 rows are 2026-09-27. C2 rows are 2026-09-30. DX8 absolute IR is not a manufacturer rating.

Cell 1Cell 2Cell 3Cell 4Cell 5Cell 6
569
549
527
542
562
551
580
569
554
568
560
554
528
523
502
518
514
488
561
540
516
529
536
521
587
570
563
573
570
554
558
554
547
544
560
547
494
503
492
509
501
493
528
537
514
518
532
540
568
570
545
564
563
571
538
548
531
542
532
544
545
544
526
545
526
530
493
497
483
501
497
501

Starred sessions are partial: 2026-09-26 is C1 only, 2026-09-30 is C2 only. Lines break there. Nothing is interpolated. IR scale is shared so C1 and C2 can be compared.

C1

Pack average IR

C1 pack average internal resistance Arrow keys move between sessions. Gaps are nights that pack or fleet was not measured.

400500600
S263S287S308S329S344S358S372S386S400S41309-26*09-26e09-2709-30*

C2

Pack average IR

C2 pack average internal resistance Arrow keys move between sessions. Gaps are nights that pack or fleet was not measured.

400500600
S263S287S308S329S344S358S372S386S400S41309-26*09-26e09-2709-30*

Rule A · C1

Intra-pack spread

Go < 40 · Caution 40–49 · Pull ≥ 50 mΩ

Inside one pack. Max cell IR minus min cell IR.

C1 intra-pack IR spread with Rule A guides Arrow keys move between sessions. Gaps are nights that pack or fleet was not measured.

0204060
Go < 40Pull ≥ 50
S263S287S308S329S344S358S372S386S400S41309-26*09-26e09-2709-30*

Rule A · C2

Intra-pack spread

Go < 40 · Caution 40–49 · Pull ≥ 50 mΩ

Inside one pack. Max cell IR minus min cell IR.

C2 intra-pack IR spread with Rule A guides Arrow keys move between sessions. Gaps are nights that pack or fleet was not measured.

0204060
Go < 40Pull ≥ 50
S263S287S308S329S344S358S372S386S400S41309-26*09-26e09-2709-30*

C1

Start floor

3600 mV watch

C1 start floor voltage with a 3600 millivolt watch line Arrow keys move between sessions. Gaps are nights that pack or fleet was not measured.

350036003700
3600 mV watch
S263S287S308S329S344S358S372S386S400S41309-26*09-26e09-2709-30*

C2

Start floor

3600 mV watch

C2 start floor voltage with a 3600 millivolt watch line Arrow keys move between sessions. Gaps are nights that pack or fleet was not measured.

350036003700
3600 mV watch
S263S287S308S329S344S358S372S386S400S41309-26*09-26e09-2709-30*

Rule B

Inter-pack rest-Δ

Go ≤ 0.30 · Caution 0.30–0.60 · Hard stop > 0.60 V

Across packs on a fleet: highest rest voltage minus lowest, for every pack measured that night. Separate from the next-parallel board delta above.

Inter-pack rest voltage delta for C1 and C2 with Rule B guides Arrow keys move between sessions. Gaps are nights that pack or fleet was not measured.

0.000.501.00
Go ≤ 0.30Hard stop > 0.60
S263S287S308S329S344S358S372S386S400S41309-26*09-26e09-2709-30*

Reserved

Capacity in / out

not in DX8 Storage data yet

Storage logs are IR and voltage only. No capacity in, capacity out, or cost per cycle.

Six cells

Per-cell IR

Per-cell internal resistance for C1-P1 across storage sessions Arrow keys move between sessions. Gaps are nights that pack or fleet was not measured.

400500600
S263S287S308S329S344S358S372S386S400S41309-26*09-26e09-2709-30*