OK
7
C1-P2 · C1-P6 · C2-P1 · C2-P3 · C2-P4 · C2-P5 · C2-P6
C1 and C2 · CNHL Black Series V2
Twelve packs, read from iCharger DX8 storage charges. Calls below are the live status table. Charts use the IR store and leave partial nights as gaps.
OK
7
C1-P2 · C1-P6 · C2-P1 · C2-P3 · C2-P4 · C2-P5 · C2-P6
Caution
3
C1-P3 · C1-P4 · C2-P2
OFF
2
C1-P1 · C1-P5
Last C1 night
2026-09-27
Call date 2026-09-27
Last C2 night
2026-09-30
Call date 2026-09-30
Mean IR
536.9mΩ
Mean of the 12 latest pack averages
Measured packs only
Mean pack IR for C1 and C2 across sessions Arrow keys move between sessions. Gaps are nights that pack or fleet was not measured.
Board call from the status file. Rest-Δ here can drop packs marked OFF. The Rule B chart further down is the full measured set.
C1
Verbatim from the status file. C1 as of 2026-09-27. C2 as of 2026-09-30. Latest IR, spread, and floor are each pack's last measured night, shown beside the call.
Chronic Cell6 self-discharge (floor 3509 mV, imb 191 mV ≥~150 SD)
worse vs eve
Call 2026-09-27 · IR 550.0 · spr 42 · floor 3509
spr 26; floor OK
Call 2026-09-27 · IR 564.2 · spr 26 · floor 3634
spr 40 + floor 3578 EYE (<3600); imb 122 not SD — still ON next board
Call 2026-09-27 · IR 512.2 · spr 40 · floor 3578
Chronic Cell1 pack-max IR 561; spr 45 Caution; floor OK (not SD); reduced C1 amps; not scrap
Call 2026-09-27 · IR 533.8 · spr 45 · floor 3603
floor 3539 EYE + lowest rest; spr 33 Go / imb 71 not SD — not scrap; off keeps board rest-Δ GO (prefer off tonight)
Call 2026-09-27 · IR 569.5 · spr 33 · floor 3539
spr 16
Call 2026-09-27 · IR 551.7 · spr 16 · floor 3644
spr 17
Call 2026-09-30 · IR 498.7 · spr 17 · floor 3698
floor 3597 EYE; imb 103 not SD; spr 26 Go — still ON
Call 2026-09-30 · IR 528.2 · spr 26 · floor 3597
spr 26
Call 2026-09-30 · IR 563.5 · spr 26 · floor 3661
spr 17
Call 2026-09-30 · IR 539.2 · spr 17 · floor 3686
spr 19
Call 2026-09-30 · IR 536.0 · spr 19 · floor 3681
spr 18; lowest C2 pack avg
Call 2026-09-30 · IR 495.3 · spr 18 · floor 3694
Latest night per pack
Color is this fleet's latest-cell range, cooler for lower IR. C1 rows are 2026-09-27. C2 rows are 2026-09-30. DX8 absolute IR is not a manufacturer rating.
Starred sessions are partial: 2026-09-26 is C1 only, 2026-09-30 is C2 only. Lines break there. Nothing is interpolated. IR scale is shared so C1 and C2 can be compared.
C1
C1 pack average internal resistance Arrow keys move between sessions. Gaps are nights that pack or fleet was not measured.
C2
C2 pack average internal resistance Arrow keys move between sessions. Gaps are nights that pack or fleet was not measured.
Rule A · C1
Inside one pack. Max cell IR minus min cell IR.
C1 intra-pack IR spread with Rule A guides Arrow keys move between sessions. Gaps are nights that pack or fleet was not measured.
Rule A · C2
Inside one pack. Max cell IR minus min cell IR.
C2 intra-pack IR spread with Rule A guides Arrow keys move between sessions. Gaps are nights that pack or fleet was not measured.
C1
C1 start floor voltage with a 3600 millivolt watch line Arrow keys move between sessions. Gaps are nights that pack or fleet was not measured.
C2
C2 start floor voltage with a 3600 millivolt watch line Arrow keys move between sessions. Gaps are nights that pack or fleet was not measured.
Rule B
Across packs on a fleet: highest rest voltage minus lowest, for every pack measured that night. Separate from the next-parallel board delta above.
Inter-pack rest voltage delta for C1 and C2 with Rule B guides Arrow keys move between sessions. Gaps are nights that pack or fleet was not measured.
Reserved
not in DX8 Storage data yet
Storage logs are IR and voltage only. No capacity in, capacity out, or cost per cycle.
Six cells